LED Drivers (IP20)

Non-Dimmable Electronic Control Gear With Active PFC

Features:

  • Universal AC input 90VAC ~ 300VAC
  • Protections: Short Circuit / Over current / Over voltage / Over Temperature
  • Cooling by free air convection.
  • Class II Power Unit, no FG
  • Built in active PFC function
  • Small and Compact size
  • 100% Full Load Burn-in Test
  • Suitable for built in applications of LED Lighting.
  • High reliability, Low Cost.

Specifications:

MODEL 20035 20050 20070 24035 24050 24070 30050 30070 30100 30125
Output Rated Current 350mA 500mA 700mA 350mA 500mA 700mA 500mA 700mA 1000mA 1250mA
LED Operation Voltage 43~57V 30~40V 21~28V 51~68V 36~48V 25~34V 45~60V 32~42V 22~30V 18~24V
Typical Output Power 20W 24W 30W
Current Accuracy ±5%
Input Voltage Range 90VAC ~ 300VAC
Current @230VAC (Typ.) 107mA 129mA 161mA
Frequency Range 45Hz – 65Hz
Power Factor >0.97 at 100% load
ATHD <10%
Efficiency >87%
Inrush Current <10A At 230VAC
Protection Open LED Protection Hiccup mode, recovers automatically after fault condition is removed
Short Circuit Hiccup mode, recovers automatically after fault condition is removed
Environment Amb. Temp. Range -10°C to 40°C.
Working Humidity 20 to 90%RH Non Condensing.
Storage Temp Humidity -20 to 85°C, 10 to 95% RH.
Safety & EMC Safety Standard Designed to meet IS 15885-2-13,UL60950-1
Withstand Voltage I/P-O/P : 3KVAC
EMC Emmision Designed to meet EN61000-3-2 Class C(>=75% load); EN61000-3-3
EMC immunity Designed to meet EN61000-4-2,3,4,5,6,8,11, EN61547, Light industry level (Surge 2KV), Criteria A
Others Cooling Natural Cooling.
Enclosure Protection IP 20
Dimension 115 x 45 x 28mm (L*W*H)
Note 1. All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25Deg.C ambient temperature.
2. Tolerance : includes set up tolerance ,line regulation and load regulation.
3. Specifications are subject to change without prior notice due to constant improvement in design & technology.
4. Constant current operation region is within 75% ~ 100% rated output voltage. This is the suitable operation
region for LED related applications, but please reconfirm special electrical requirements for some specific system design.